EICAS "STARTER CUTOUT _ " (SW)

Indications:
  • EICAS msg "STARTER CUTOUT _"
  • Start valve open light remains illuminated beyond 52% N2 (Note: Start Switch may retract normally at around 50% N2 or remain latched out)
Probable Causes:
  • Engine Start Switch selector may remian in Start position (latched out); Starter Switch System
Actions:
  • DO NOT ABORT START - to avoid damaging the starter
  • Wait for engine to stablise
  • Call for "STARTER CUTOUT _" Checklist
  • Inform ATC and GND
  • No applicable CB
  • Check MEL
Note:
  • If msg no longer displayed after start sw push in + start valve open light extinguished, most likely Starter Switch System fault, check MEL 80-11-2 Start Switch Systems.
  • If msg stay shown + start valve open light remain illuminated (ie Start Valve in OPEN position; according to MEL, "dispatch with Engine Start Valve inoperative in open position is not permitted"), NO GO
  • >> Engine bleed air switch - Off
  • >> Shutdown affected engine; return to bay for maintenance
  • Maintenance action is required
  • Coordinate with ATC and GND for return to bay
  • Complete "AFTER LANDING CHECKS" prior to parking

Circuit Breaker(s):

  • NO
MEL:
  • MEL 80-11-2 Start Switch Systems

Common Errors:
  • Calling for C/L prior to engine parameters stablised
  • Confuse switch malfunction with start valve malfunction
  • Read wrong MEL