Start Valve Open Light InOp

Indications:
  • Start Valve Open Light latches in start position but not illuminated
  • Engine Bleed PRSOV Off Light extinguished
  • N2, N1, oil pressure normal
Actions:
  • Carry out light test to check Start Switch Bulb operation
  • Continue until 52% N2 with all other start indications normal; Start Valve closure can be confirmed after 52% N2 by, (a) a decrease in duct pressure, (b) absence of EICAS msg "STARTER CUTOUT _"
  • If not normal indications, discontinue start; Push Start Switch in (by recall)

Circuit Breaker(s):
  • NO
MEL:
  • MEL 80-11-4 Start Valve Open Lights

Common Errors:
  • Interpreting indications as Start Valve fail to open
  • Not doing light test
  • Not checking MEL